NSD Standard Extension Sensor Cable for ABSOCODER
Extension sensor cable for NSD standaed is the cable which connects an ABSOCODER sensor to converter.
Select cables from usage and environment.
NSD standard sensor type
Model coding
Model | ①Number of twist pairs |
②Applicable ABSOCODER sensor |
③Cable type | ④Connector type of converter or controller side |
⑤Connector type of sensor side |
⑥Cable length [Units : m] |
---|---|---|---|---|---|---|
3P-S -0102-□ |
3 | P | S | 01 | 02 | 2,3,5,8,10, 15,20,25,30, 35,40,45,50 |
3P-RBT -0102-□ |
3 | P | RBT | 01 | 02 | |
4P-S -0102-□ |
4 | P | S | 01 | 02 | |
4P-RBT -0102-□ |
4 | P | RBT | 01 | 02 | |
3S-RBT -0102-□ |
3 | S | RBT | 01 | 02 | 2,3,5,8,10, 15,20,25,30,35,40 |
3S-RBT -0103-□ |
3 | S | RBT | 01 | 03 | 4,6,8,10,15, 20,25,30,35,40 |
4P-RBT -0103-□ |
4 | P | RBT | 01 | 03 |
- ①Number of twist pairs
- 3[3-pairs] 4[4-pairs]
- ②Applicable ABSOCODER sensor
- P[Standard type] S[High-resolution type]
- ③Cable type
- S[Standard cable] RBT[Robotic cable]
- ④Connector type of converter or controller side
- 01[R04-PB9M8.0A]
- ⑤Connector type of sensor side
- 02[R04-JB9F8.0A] 03[R04-PB9F8.0A]
- ⑥Cable length
- We will provide the cable every 10m if you would like to purchase longer than 50m.
Specification
NSD cable specifications
Item | Specification | ||||
---|---|---|---|---|---|
Model code | 3P-S | 4P-S | 3P-RBT | 4P-RBT | |
Cable type | Standard cable | Robotic cable | |||
Diameter | Φ8 | ||||
Rated voltage | 30VAC | ||||
Ambient temperature |
Operating | -5 ~ +60℃ | -5 ~ +60℃ | ||
Storage | -5 ~ +60℃ | -10 ~ +60℃ | |||
Insulator | Irradiated cross linked foamed polyethylene | ETFE plastic | |||
Sheath | Polyvinyl chloride mixture | ||||
Color of sheath | Gray | Black | |||
Advantage | Extendable for long distance | Superior flexibility; ideal for moving place | |||
Applicable ABSOCODER | VRE-P028 VRE-P062 CSA cylinder |
MRE-32SP062 MRE-G□SP062 VLS-□PW |
VRE-P028 VRE-P062 CSA cylinder |
MRE-32SP062 MRE-G□SP062 VLS-□PW |
High-resolution type sensor cable specifications
Item | Specification | |
---|---|---|
Model code | 3S-RBT | |
Cable type | Robotic cable | |
Diameter | Φ8 | |
Rated voltage | 30VAC | |
Ambient temperature |
Operating | -5 ~ +60℃ |
Storage | -10 ~ +60℃ | |
Insulator | ETFE plastic | |
Sheath | Polyvinyl chloride mixture | |
Color of sheath | Blue | |
Advantage | Superior flexibility; ideal for moving place | |
Applicable ABSOCODER | VRE-16TS062 |
Combination
Single-turn type ABSOCODER sensor VRE
Smart linear position sensing cylinder type CSA
High-resolution Single-turn type ABSOCODER sensor VRE
Multi-turn type ABSOCODER sensor MRE
Linear type ABSOCODER sensor VLS
Dimensions
Extension Sensor Cable
3P-S-0102 / 3P-RBT-0102 / 4P-S-0102 / 4P-RBT-0102 / 3S-RBT-0102
Extension Sensor Cable
3S-RBT-0103 / 4P-RBT-0103
Restrictions when an extension comprises both standard and robotic cables
When extending the cable connecting the converter to the sensor, a standard cable (S) is used at the fixed area, and a robotic cable (RBT) is used at the movable area.
In cases such as this, where both cable types are used in the extension, the maximum cable length is shorter than when using a standard cable only.
Therefore, be sure that the length is within the prescribed range.
If the prescribed length is exceeded, abnormal operation may occur. The required robotic cable length should be determined first, then calculate the maximum standard cable extension length using the method shown here.
(1) Refer to the information about your converter or controller to find specifications for the longest allowable extended sensor cable length
for each cable type (the allowable length varies depending on the converter and sensor combination).
a. Maximum standard cable extension length:L1 (m)
b. Maximum robotic cable extension length:L2 (m)
(2) The robotic cable length (Lr) should be determined with reference to the drawing, and by measuring, etc. Be sure that the "b (L2)" length given above is not exceeded.
(3) The maximum standard cable extension length (Ls) can be calculated using the formula shown at right.
Calculation formula
and cable configuration